Power Systems Technical Articles

Our experts continuously work on power systems problems, and we share solutions with Practical Reference Articles.

The main topics are earthing system modeling, power cable ratings, HV/LV electrical design, protective device coordination, and arc flash studies. We cover IEC and IEEE standards.

Join 23K+ engineers and get our latest technical articles direct to your inbox as they are releasedJayson Patrick

This field is for validation purposes and should be left unchanged.
Photo of Jayson Patrick for Technical Articles page about electrical power systems Design

Choose the article category

8 mins read
Explore the factors affecting cable ampacity in trays, including thermal and electromagnetic effects. Learn calculation methods and best practices for safe power cable installations.
Based on extensive field experience, this article recommends the best materials for cable trays for use in offshore facilities such as offshore wind, solar, and oil rigs.
5 mins read
It's difficult to decide on the thermal resistivity of soil or backfill to use for cable rating studies. The typical thermal resistivities of common native soils and engineered materials used as backfills for buried cables are provided in tables.
5 mins read
The widely accepted maximum operating temperature of XLPE insulated power cables under “normal use” conditions is 90 ˚C. During emergencies, the temperature of a buried cable may be permitted to exceed this temperature. The duration considered for such emergencies ranges from 10 minutes up to 15 days. In many countries, XLPE-insulated cables are allowed to operate up to 100-105 ˚C for short durations.
9 mins read
We performed ampacity calculations for hundreds of industrial and utility power cables from Southwire. The assumptions used for modelling in the software are explained. The calculated ampacities were all within 3 % of the values given in ICEA and NEC standards.
4 mins read
The standard HV cable rating calculation methods do not cover all real-world situations. This article proposes a new method of finding the current rating for 10 cables touching in the air.
17 mins read
Explains the effects of the installation conditions and the bonding arrangement on the current rating of high voltage power cables.
7 mins read
The AC resistance of a cable conductor is always larger than the DC resistance. The primary reasons are ‘skin effect’ and ‘proximity effect’. Equations and example calculations are provided in this article.
8 mins read
Accurate high voltage cable current ratings achieved - ELEK Cable HV software matches CIGRE TB 880 and performs IEC 60287 compliant calculations.