Software for Accurate Cable Ampacity Ratings
Custom cables and arrangements. A wide range of installation conditions. User-friendly with validated results.
These Power utilities and government use Cable High Voltage Software™️
These Consulting companies use Cable High Voltage Software™️
These Construction companies use Cable High Voltage Software™️
These Manufacturers and suppliers use Cable High Voltage Software™️
These Mining companies use Cable High Voltage Software™️
Everything you need for power cable current rating calculations
Pricing Options to Suit Everyone
Cable HV Software is available in two edition choices, and you can choose from perpetual or leased licences. We also offer our Power Bundle.
Prices are in AUD currency and exclude GST. For a quote in USD, GBP, or EUR please contact us.
- Actual price may vary based on the exchange rate in place between AUD and at the time of payment processing or invoicing.
Perpetual Licence
Leased Licence
Cable High Voltage (Base)
AUD5,990Add to cart
1 Year of Updates & Support Included
Provides a wide range of installations conditions. Cables from LV up to 500 kV.
- Custom cable modelling.
- Unenclosed in air - exposed or sun or shaded.
- Enclosed in ducts/conduits.
- Groups of cables.
- Direct buried - optionally consider dry-out of soil.
- Backfilled trenches (areas with different soil thermal resistivity).
- Buried in ducts/conduits.
Cable High Voltage (Full)
1 Year of Updates & Support Included
Includes all add-on modules.
- All features from the Base edition.
+
- Cyclic and emergency ratings.
- Short-circuit rating.
- Magnetic fields module.
- Filled cable trays.
- Unfilled troughs.
- Multiple circuits crossing.
- Sequence impedances.
- Direct to Excel™ reports.
+
Power Bundle
AUD27,380 Original price was: AUD27,380.AUD19,300Current price is: AUD19,300.Add to cart
Bundle and save
Get Cable High Voltage along with licences for all our other products.
- Cable High Voltage (Full)
+
Cable HV (Standard)
AUD14,900Add to cart
1 Year of Updates & Support Included
Cable current rating calculations to IEC 60287 with add-on modules. Accuracy validated with CIGRE TB 880.
- Custom cable modelling including database of pre-modelled cables.
- Wide range of Installation Methods - In Air, In Groups, Buried (with soil dry-out), Backfilled and duct banks.
+
- Short-circuit Ratings.
- Magnetic Fields Module.
- Filled Cable Trays Module.
- Unfilled Troughs Module.
- Multiple Circuits Crossing Module.
- Ventilated Tunnels Module.
- Risers and J-tubes Module.
- Sequence Impedances.
- Armour Loss to CIGRE TB 908.
- Direct to Excel™ reports.
- Metric and Imperial units.
Cable HV (Professional)
AUD20,700Add to cart
1 Year of Updates & Support Included
Includes all add-on modules with FEM and transient (cyclic and emergency) ratings, HVDC ratings, and advanced soil drying.
- All features of Standard edition.
+
- Cyclic and Emergency Ratings.
- HVDC Cable Current Ratings.
- Advanced Soil Drying - Multiple Circuits and In Backfill.
- Finite Element Method (FEM) Module.
FEM module includes:
Convection on ground surface, automatic meshing, multiple backfills or zones of different soil resistivity, capabilities beyond the limitations of IEC 60287.
+
Power Bundle
AUD27,380 Original price was: AUD27,380.AUD19,300Current price is: AUD19,300.Add to cart
Bundle and save
All our power systems software.
Save 30% on individual pricing.
- Cable High Voltage (Standard)
+
3 Months
AUD4,900Add to cart
Technical & Engineering Support Included
Cable current rating calculations to IEC Standards with add-on modules.
- Standard edition.
- Modules from Standard edition included.
6 Months
AUD7,100Add to cart
Technical & Engineering Support Included
Cable current rating calculations to IEC Standards with add-on modules.
- Standard edition.
- Modules from Standard edition included.
12 Months
AUD9,500Add to cart
Technical & Engineering Support Included
Cable current rating calculations to IEC Standards with add-on modules.
- Standard edition.
- Modules from Standard edition included.
See How We Compare
We ran an in-depth comparison between ELEK Cable High Voltage and major competitor CYMCAP. You can review several different cases, with supporting PDF reports on each product in each case.
Why Our Customers Choose Cable High Voltage
Start Your Free Trial Today
With a choice of editions, or a free trial, and instant downloads, you could be minutes away from fast, accurate calculations.
Outstanding Features and Capabilities
Wide Range of Installation Methods
Standards IEC 60287 Series, IEC 60853-2, IEC 60949.
Validated with CIGRE TB 880. Armour losses to CIGRE TB 908.
In Air and Groups in Air
Unenclosed - exposed to sun or shaded. Enclosed in ducts. Groups of multi-core or single core cables. Adjust ambient air temperature.
Bonding Arrangements
Considers cable circulating and eddy current losses. Solid, single-point or cross-bonded earthing arrangements.
Direct Buried or In Ducts
Equally or unequally loaded multiple buried circuits in any custom arrangement of any cable type. Soil dry-out around cables.
Buried in Thermal Backfill
Multiple custom cable arrangements buried direct or in ducts in thermal backfill. Soil temperature plots.
Unfilled Troughs
Cables ratings for cables installed in unfilled cable troughs where the trough is buried and covered on all sides up to ground level.
Ventilated Tunnels
Calculates current ratings for multiple circuits installed inside custom tunnels with ventilation to IEC 60287-2-3.
Risers & J-tubes
Cables installed in risers with open ends, one end open or closed at both ends. Current ratings for cables in tubes for offshore wind farms.
Finite Element Method
Extends beyond the limitations of the IEC Standards. For example, models multiple zones of soil with different thermal resistivity.
Risers & J-tubes
Cables installed in risers with open ends, one end open or closed at both ends. Current ratings for cables in tubes for offshore wind farms.
Finite Element Method
Extends beyond the limitations of the IEC Standards. For example, models multiple zones of soil with different thermal resistivity.
Major Features Include
Save 30% from buying the each item separately
Add-on Modules
Powerful add-on modules that significantly extend the capabilities.
Emergency and Cyclic Ratings
Transient rating calculations to Standard IEC 60853 and Neher-McGrath methods.
Short-circuit Ratings
Adiabatic and non-adiabatic short-circuit ratings for metallic components (automatically detected) of custom cables.
Magnetic Fields
Magnetic field density in micro Tesla at any height above the ground for any arrangement of buried or in air cables.
Multiple Cable Crossings
Calculate derating to IEC 60287-3-3 for one or multiple cable circuits or heat pipes crossing at any angles.
Sequence Impedances
Automatic calculation of the positive, negative, and zero sequence of cables as well as the surge impedance based on the installation and the cable models.
Randomly Filled Cable Trays
Ratings for cables installed in bundles in cable trays with options for fire-rated insulation, cable tray covers, custom diversity and solar radiation.
Finite Element Method Module
FEM is the most accurate method for cable current rating calculations.
Beyond IEC 60287 Limitations
Installation methods which can be modelled in FEM includes: any combination of direct buried, multiple backfills, filled troughs and multiple cable circuits.
Accurate Buried Ratings
The IEC standards assume an isothermal (ideal) ground surface whereas FEM considers convection leading to more accurate ratings.
Multiple Backfills
Model areas with different thermal resistivity including multiple separated backfills or zones of soil with different thermal resistivity.
Automatic Meshing
The FEM algorithm automatically meshes the environment as well as all cable components for high accuracy node temperature calculations.
Graphical Cable Modelling
Very easily build custom cable models based on their construction.
Custom Cable Models
Using the datasheet or manufacturers catalog easily build cable models for custom rating calculations.
Database of Pre-built Cables
Includes hundreds of pre-modelled cables from LV up to any AC voltage, and DC cables.
Multiple Cable Types
Single core or multi-core, DC, single phase or 3 phases. Copper or aluminium. Screened, sheathed or armoured cables.
Variable Frequency
Use for 50 Hz or 60 Hz systems and high frequency applications such as motor drives.
Advanced Reporting
Beautiful, comprehensive and easy to understand reports.
PDF Reports
Create full and detailed reports in PDF format.
Detailed Results
All the results from the losses and thermal resistance calculations.
Your Company Logo
Add your own company logo and custom fields to the reports.
Direct to Microsoft Excel
Reports can be generated directly into Microsoft Excel files.
Start Your Free Trial Today
With a choice of editions, or a free trial, and instant downloads, you could be minutes away from fast, accurate calculations.
Frequently Asked Questions
Yes, easily from manufacturer datasheets. A database of 1200+ pre-modelled cables is also included.
Yes, from low voltage (LV) up to any AC voltage or up to 5 kV for DC.
Yes, you can design your installation and/or cable models using imperial units (feet/inches).
Yes with the latest IEC standards and their amendments as well as other relevant technical publications.
The standards change occasionally, usually every few years. When the standards do change we will update the software within 6 months, which is the expected time for everyone to comply. The software itself will notify you during its use or you will be contacted via email of a new version being available for download.
Via instant download. Link to download, activation code and invoice emailed immediately (24/7) after purchase.
Each licence of ELEK Cable HV can be used by up to 2 users at the same time. You can install the software onto any number of PCs in your business in any locations. A simple online 24/7 activation process is used. The software licence is easily deactivated by any user and moved between PCs.
Updates and Support payment is due after the first year which is 20 % of the current licence price.
Unlimited licence transfers/deactivations is dependent on having up-to-date Updates and Support.
. We regularly update our software, not just for new Standards, but to add new features and improvements.
Yes, you can upgrade from the Base to Full edition at any time, by simply contacting us and paying the difference.
We're Here To Help
Our software is designed to be simple and intuitive, but if you need a helping hand, we have a support team and range of online resources to help get you get up to speed quickly.
First Class Support
Our expert team is on-hand to assist you with any questions you have or assistance you need with our software range.
Top Notch Guidance
Dive into our library of tutorials to expand your skills and get more from Cable High Voltage.
Start Your Free Trial Today
With a choice of editions, or a free trial, and instant downloads, you could be minutes away from fast, accurate calculations.
About Us
We're Here For You
Electrotechnik is an electrical software company founded in 2009.
We provide software solutions to the electrical design industry. Our vision is to provide the world’s best and most innovative electrical software for engineers and electrical contractors.
Our software is developed and supported by an experienced team from our head office.