Power Systems Technical Articles

Our experts continuously work on power systems problems, and we share solutions with Practical Reference Articles.

The main topics are earthing system modeling, power cable ratings, HV/LV electrical design, protective device coordination, and arc flash studies. We cover IEC and IEEE standards.

Join 23K+ engineers and get our latest technical articles direct to your inbox as they are releasedJayson Patrick

This field is for validation purposes and should be left unchanged.
Photo of Jayson Patrick for Technical Articles page about electrical power systems Design

Choose the article category

5 mins read
The features of ELEK Cable HV software and CYMCAP software are compared in detail.
Waveform cables are commonly used in the UK for low-voltage power networks. The term waveform refers to the way the neutral/earth wires are laid around the cores/bedding. Using this configuration enables the neutral/earth wires to be opened so a connection can be made to the conductors anywhere along its length.
10 mins read
The definition of emergency rating is the permissible short-term rating of a cable already loaded and at a steady-state, considering the thermal capacitances and the thermal resistances of an installed cable system. The definition of cyclic rating is the maximum current of a cable when the load is varied in a sequence of steps that are repeated cyclically. The cyclic rating differs for different sequences and different cycle periods. Both emergency and cyclic ratings deal with time-varying loads
6 mins read
The principle of economic cable sizing is to select a minimum cable size that is safe to use and the cost of the losses over the lifetime is also minimised.
3 mins read
Explains the fundamentals of oil-filled cables current rating calculations to IEC 60287 and provides and example calculation for a 400 kV single core cable.
3 mins read
The new maximum demand module provides fast and accurate calculations for loads in accordance with rules from the Standards and for custom loads. An ingenious automatic phase balancing algorithm ensures maximum demand and phase imbalance are both minimised.
4 mins read
The purpose of transmission line grounding is to provide adequate lightning performance of the line; and effectively dissipate fault current avoiding the build-up of unsafe step and touch potentials around the tower base.
3 mins read
Metal earthing rods that are encased inside concrete will have a lower resistance. Concrete has a typical electrical resistivity of between 30 Ohm.m to 200 Ohm.m.
This article explains how to calculate the current rating of cables in J-tubes. Typically J-tubes are the thermal bottleneck of submarine power cable routes.