Photo of Jayson Patrick for Technical Articles page about electrical power systems Design

Choose the article category

3 mins read
Metal earthing rods that are encased inside concrete will have a lower resistance. Concrete has a typical electrical resistivity of between 30 Ohm.m to 200 Ohm.m.
The effects of lightning strikes on earthing or protection systems designed to IEC 62305 can be modelled using an equivalent single frequency from 25kHz up to 1MHz which gives similar results to a time-domain approach. This article provides the frequency and current values to be used for modelling lightning.
7 mins read
We've reviewed the top 3 electrical engineering design software packages in 2024 that are designed for Australian conditions and electrical standards. We've compared the features, capabilities, pricing, and technical support.
4 mins read
The purpose of transmission line grounding is to provide adequate lightning performance of the line; and effectively dissipate fault current avoiding the build-up of unsafe step and touch potentials around the tower base.
5 mins read
Copper is often preferred for its superior electrical properties, while aluminum and galvanized steel are chosen for cost-effectiveness. Copper-clad steel can offer a balance between cost and performance. This article demonstrates which option is best for different scenarios.
This report shows the effects of a direct lightning strike to an air terminal installed on top of a building which is connected to a buried earthing system.
4 mins read
Learn about thermal analysis for HVDC submarine cables, focusing on the 2 K Criterion to minimize environmental impacts.
4 mins read
The standard HV cable rating calculation methods do not cover all real-world situations. This article proposes a new method of finding the current rating for 10 cables touching in the air.
6 mins read
The principle of economic cable sizing is to select a minimum cable size that is safe to use and the cost of the losses over the lifetime is also minimised.