Power Systems Technical Articles

Our experts continuously work on power systems problems, and we share solutions with Practical Reference Articles.

The main topics are earthing system modeling, power cable ratings, HV/LV electrical design, protective device coordination, and arc flash studies. We cover IEC and IEEE standards.

Join 23K+ engineers and get our latest technical articles direct to your inbox as they are releasedJayson Patrick

This field is for validation purposes and should be left unchanged.
Photo of Jayson Patrick for Technical Articles page about electrical power systems Design

Choose the article category

7 mins read
The features of ELEK Cable HV software and CYMCAP software are compared in detail.
Prevent solar PV cable overheating with proper trench design. Learn how cable spacing, soil thermal resistivity, and backfill impact ampacity. Case study included.
10 mins read
The definition of emergency rating is the permissible short-term rating of a cable already loaded and at a steady-state, considering the thermal capacitances and the thermal resistances of an installed cable system. The definition of cyclic rating is the maximum current of a cable when the load is varied in a sequence of steps that are repeated cyclically. The cyclic rating differs for different sequences and different cycle periods. Both emergency and cyclic ratings deal with time-varying loads
4 mins read
Experienced electrical engineers created this reference list of standards for power systems earthing/grounding for substations, renewable energy, etc.
13 mins read
The technical guide explains the electrical systems, local WTG and combined earthing system design, touch and step voltage hazards, soil electrical resistivity measurements, earth fault currents, earthing system software modelling, and validation testing of earthing for wind farms.
9 mins read
How cable crossings affect ampacity and current rating. Covers thermal hotspots, crossing angle, separation, and a practical HV case study.
8 mins read
A new calculation method based on FEM and IEC 60287 for current rating of HV cables in soils with multiple different thermal resistivities is explained with an example calculation. Modelling the different soil thermal resistivity zones (multiple backfills) is important for obtaining accurate cable current ratings.
2 mins read
Discussion of the changes to AS/NZS 3000:2018 affecting cable current-carrying capacity.
4 mins read
Reach touch voltages are different to touch voltages and automatically set to zero when the distance between the voltage point on the ground surface and the grid conductor which is touched exceeds a reach distance.