1

Your Cart

1
Subtotal: AUD499

Power Systems Technical Articles

Our experts continuously work on power systems problems, and we share solutions with Practical Reference Articles.

The main topics are earthing system modeling, power cable ratings, HV/LV electrical design, protective device coordination, and arc flash studies. We cover IEC and IEEE standards.

Sign up for my email newsletter and I will send you the latest technical articles as they are releasedJayson Patrick

Photo of Jayson Patrick for Technical Articles page about electrical power systems Design

Choose the article category

10 mins read
Most power cables have a design life of between 20 to 30 years. If the cables are not fully loaded, they are expected to last beyond their design life. The insulation is the weakest part of a cable. Montsinger's Rule states: Insulation life is halved by a temperature increase of 8 to 10 ˚C. An example calculation using the Arrhenius equation is provided.
The definition of “touch voltage” is the voltage between accessible exposed and extraneous conductive parts that may lead to the risk of electric shock in the event of an electrical fault. This article covers AS/NZS 3000, BS 7671, and NFPA 70E rules concerning touch voltages and provides the equations for calculations.
This article explains how to calculate the current rating of cables in J-tubes. Typically J-tubes are the thermal bottleneck of submarine power cable routes.
8 mins read
A new calculation method based on FEM and IEC 60287 for current rating of HV cables in soils with multiple different thermal resistivities is explained with an example calculation. Modelling the different soil thermal resistivity zones (multiple backfills) is important for obtaining accurate cable current ratings.
12 mins read
DC cable sizing has significant implications on a PV system's performance, total cost, and safety. Example calculations of Current Rating and Voltage Rise have been provided.
2 mins read
One of the main factors determining the severity of an arc flash injury is the proximity of the worker to the arc flash, also known as the working distance. Working distances from AS (ENA), IEEE, NFPA and DGUV Standards and Guides have been provided.
3 mins read
The effects of lightning strikes on earthing or protection systems designed to IEC 62305 can be modelled using an equivalent single frequency from 25kHz up to 1MHz which gives similar results to a time-domain approach. This article provides the frequency and current values to be used for modelling lightning.
5 mins read
The methods for calculating the current rating of multiple cables installed in ventilated tunnels are explained with example calculations. Overall tunnel length and air velocity inside the tunnel have a significant impact on cable current ratings.
3 mins read
The calculation of current ratings for groups of (multiple) cable circuits require the quantification of the mutual heating component between the groups of circuits. This example is for multiple groups of circuits in air on the same cable ladder. This article will discuss the IEC 60287 approach.
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors