7 mins read
Crossing multiple cables or heat sources at a crossing angle causes a current rating reduction, calculated using IEC Standard 60287.
4 mins read
New 13 kV power circuits will be installed in an unfilled trough with ventilated covers. These new circuits will cross with existing buried 400 kV cables at approximately 90 degrees with a continuous current rating requirement of 1136 MVA (1640 A) per phase for all seasons.
10 mins read
Most power cables have a design life of between 20 to 30 years. If the cables are not fully loaded, they are expected to last beyond their design life. The insulation is the weakest part of a cable. Montsinger's Rule states: Insulation life is halved by a temperature increase of 8 to 10 ˚C. An example calculation using the Arrhenius equation is provided.
The definition of “touch voltage” is the voltage between accessible exposed and extraneous conductive parts that may lead to the risk of electric shock in the event of an electrical fault. This article covers AS/NZS 3000, BS 7671, and NFPA 70E rules concerning touch voltages and provides the equations for calculations.
This article explains how to calculate the current rating of cables in J-tubes. Typically J-tubes are the thermal bottleneck of submarine power cable routes.
8 mins read
A new calculation method based on FEM and IEC 60287 for current rating of HV cables in soils with multiple different thermal resistivities is explained with an example calculation. Modelling the different soil thermal resistivity zones (multiple backfills) is important for obtaining accurate cable current ratings.
12 mins read
DC cable sizing has significant implications on a PV system's performance, total cost, and safety. Example calculations of Current Rating and Voltage Rise have been provided.
2 mins read
One of the main factors determining the severity of an arc flash injury is the proximity of the worker to the arc flash, also known as the working distance. Working distances from AS (ENA), IEEE, NFPA and DGUV Standards and Guides have been provided.
3 mins read
The effects of lightning strikes on earthing or protection systems designed to IEC 62305 can be modelled using an equivalent single frequency from 25kHz up to 1MHz which gives similar results to a time-domain approach. This article provides the frequency and current values to be used for modelling lightning.