Our experts continuously work on power systems problems, and we share solutions with Practical Reference Articles.

The main topics are earthing system modeling, power cable ratings, HV/LV electrical design, protective device coordination, and arc flash studies. We cover IEC and IEEE standards.

Join 23K+ engineers and get our latest technical articles direct to your inbox as they are releasedJayson Patrick

This field is for validation purposes and should be left unchanged.
Photo of Jayson Patrick for Technical Articles page about electrical power systems Design

Choose the article category

This article explains why dynamic ratings are important when dealing with long AC cables for wind farms. An example calculation of a dynamic rating which uses the measured load profile is given.
Waveform cables are commonly used in the UK for low-voltage power networks. The term waveform refers to the way the neutral/earth wires are laid around the cores/bedding. Using this configuration enables the neutral/earth wires to be opened so a connection can be made to the conductors anywhere along its length.
10 mins read
This article analyses the magnetic fields produced by electrical power cables installed in various configurations under varying conditions in the context of a health and safety-related issue. A software program has been used for calculating the results based on the Biot-Savart law. Techniques for the mitigation of magnetic fields are also presented.
6 mins read
Direct lightning strikes to substations causes physical damage and poses hazards for people.
3 mins read
Using bentonite to reduce resistance Sometimes it is not possible to achieve the desired reduction in ground resistance by adding more grid conductors or ground rods. An alternate solution is to effectively increase the diameter of the electrode by modifying the soil surrounding.
1 min read
Download the attached PDF report template and use it for your solar connection applications.
2 mins read
We have benchmarked our Cable HV Software current rating results for 110 kV cables against the well-known software CYMCAP. We have shown the results are virtually identical (under 1.5 % difference).
5 mins read
This article explains how to perform cable pulling tension and sidewall pressure calculations and also includes an example.
3 mins read
The new maximum demand module provides fast and accurate calculations for loads in accordance with rules from the Standards and for custom loads. An ingenious automatic phase balancing algorithm ensures maximum demand and phase imbalance are both minimised.