Standards for Power Systems Earthing Design

Reference list of standards for power systems earthing/grounding categorised by applications

Table of Contents

Who created this list of earthing Standards?

Experienced electrical earthing design engineers with years of hands-on project expertise have developed this reference list of standards for power systems earthing.

These professionals have drawn on their extensive knowledge to compile a comprehensive guide that ensures compliance, safety, and reliability across various applications. From substations to renewable energy systems, the standards outlined here reflect industry best practices and are tailored to meet the diverse needs of modern electrical installations.

Where do the important earthing standards come from?

The most important earthing standards are developed by globally recognised organisations that specialise in electrical engineering, safety, and power system design. These organisations bring decades of expertise and research to create guidelines that ensure the safe operation of power systems across various industries. Here is an overview of the key contributors:

1. International Electrotechnical Commission (IEC)

The IEC is a global standards organisation that focuses on electrical, electronic, and related technologies. It develops internationally accepted standards that ensure compatibility, safety, and efficiency in power systems worldwide.

2. Institute of Electrical and Electronics Engineers (IEEE)

The IEEE is a leading professional association for electrical and electronics engineering. It publishes highly regarded standards that address technical aspects of power systems, including grounding, resistivity measurement, and renewable energy applications.

3. Australian/New Zealand Standards (AS/NZS)

AS/NZS standards are tailored to the specific requirements of Australia and New Zealand. They address local safety regulations, environmental conditions, and industry needs, ensuring compliance with regional practices.

4. British Standards Institution (BSI)

The BSI develops standards that serve as benchmarks for safety and performance in electrical installations. Its work is widely adopted in the UK and internationally for ensuring effective earthing practices.

5. International Council on Large Electric Systems (CIGRE)

CIGRE is a global organisation dedicated to advancing power system technology through research and technical guidance. It provides specialised insights into grounding system design and lightning performance for transmission lines.

6. Energy Networks Association (ENA)

The ENA represents electricity transmission and distribution network operators in regions such as the UK and Australia. It produces detailed guidelines for designing, testing, and maintaining earthing systems in power networks.

7. Electric Power Research Institute (EPRI)

EPRI conducts research to enhance the reliability, efficiency, and safety of power systems. Its contributions include innovative guidelines for emerging technologies like high-voltage direct current (HVDC) systems. These organisations collectively shape the global framework for earthing standards, ensuring consistency, innovation, and safety across diverse applications in power systems engineering.

List of Standards for Power Systems Earthing Design

Power systems earthing is a critical component of electrical safety and performance. Below is a comprehensive list of standards categorised by their specific applications, with additional standards included.

1. Substation Earthing

2. Testing of Earthing Systems

3. Touch/Step Voltage Limits

4. Renewable Energy Systems

5. Metallic Pipelines Safety

6. Industrial & Commercial Earthing

7. Overhead Lines

8. High Voltage DC Systems

9. Data Centres Earthing

10. Telecommunications

11. Fault Current Distribution

SafeGrid Earthing Software

Easily design safe earthing systems in compliance with Standards.

Related Articles:

Understand how software simulations enhance grid impedance tests, improving accuracy and efficiency in earthing system design and performance evaluation.
This report explains how to perform accurate earth fault current analysis for substations connected by cable transmission lines. Earth fault currents for simple cable and overhead transmission lines are explained first. Next, two case studies involving hybrid cable transmission lines are presented.
Copper is often preferred for its superior electrical properties, while aluminum and galvanized steel are chosen for cost-effectiveness. Copper-clad steel can offer a balance between cost and performance. This article demonstrates which option is best for different scenarios.
The technical guide explains the electrical systems, local WTG and combined earthing system design, touch and step voltage hazards, soil electrical resistivity measurements, earth fault currents, earthing system software modelling, and validation testing of earthing for wind farms.
There are two reasons, according to the standards, why crushed rock or gravel is laid in substations, as explained in this article.
During an earth fault on a substation earth grid, the flow of current to the earth will produce voltage gradients. An earth grid that is properly designed will safely dissipate current into the ground.

Print this article:

Print

SafeGrid Earthing Software

An electrical device with software and a graph on its screen.

Easily design safe earthing systems in compliance with Standards.

As used by:

SafeGrid Earthing Clients