Prices shown are exclusive of GST (tax). Taxes not applicable for countries outside AU.
Perpetual Licence
Leased Licence
SafeGrid (Basic)
1 Year of Updates & Support Included
Earthing systems design which is easy to use and accurate.
- Multilayer Finite Element Method calculations.
- Non-equipotential grids (accurate).
- Soil modelling from resistivity measurements.
- Custom grids of any shape or size.
- Safety criteria to IEC, IEEE and EN Standards.
*Note to International Buyers:
There will be No Taxes for the purchase of any SafeGrid Products.
SafeGrid (Standard)
AUD9,900Add to cart
1 Year of Updates & Support Included
Complete buried earthing system design package suitable for large grids.
- Multilayer Finite Element Method calculations.
- Non-equipotential grids (accurate).
- Soil modelling from resistivity measurements.
- Custom grids of any shape or size.
- Safety criteria to IEC, IEEE and EN Standards.
+
- Fault current distribution module.
SafeGrid (Professional)
AUD18,000 Original price was: AUD18,000.AUD15,000Current price is: AUD15,000.Add to cart
1 Year of Updates & Support Included
Above and below ground conductors with high-frequency capability.
- All features from Standard edition.
+
- Above and below ground earthing.
- High frequencies up to 10 MHz for lightning currents.
- Soil frequency dependency.
- Deals with extremely large and complicated grids (15,000+ conductors).
+
- Lightning shielding (rolling sphere) module.
SafeGrid (Standard)
AUD9,900Add to cart
1 Year of Updates & Support Included
Complete buried earthing system design package suitable for large grids.
- Multilayer Finite Element Method calculations.
- Non-equipotential grids (accurate).
- Soil modelling from resistivity measurements.
- Custom grids of any shape or size. Import from AutoCAD.
- Safety criteria to IEC, IEEE and EN Standards.
- Metric or Imperial units support.
+
- Lightning Shielding Module.
- Fault Current Distribution Module.
SafeGrid (Professional)
AUD18,000 Original price was: AUD18,000.AUD15,000Current price is: AUD15,000.Add to cart
1 Year of Updates & Support Included
Above and below ground conductors with transient and high-frequency capability.
- All features from Standard edition.
+
- Above and below ground earthing.
- Transient (time-domain) analysis.
- High frequencies up to 10 MHz for lightning currents.
- Soil frequency dependency.
- Seasonal analysis in soil modelling.
- Deals with extremely large and complicated grids (15,000+ conductors).
Power Bundle
AUD27,380 Original price was: AUD27,380.AUD19,300Current price is: AUD19,300.Add to cart
1 Year of Updates & Support Included
All our electrical power systems software.
Save 30% on individual pricing.
- SafeGrid Earthing (Standard)
+
3 Months
AUD3,500Add to cart
Engineering Technical Support Included
Earthing systems design software which is easy to use and accurate.
- Standard edition.
- Lightning Shielding Module.
- Fault Current Distribution.
6 Months
AUD4,500Add to cart
Engineering Technical Support Included
Earthing systems design software which is easy to use and accurate.
- Standard edition.
- Lightning Shielding Module.
- Fault Current Distribution.
12 Months
AUD6,000Add to cart
Engineering Technical Support Included
Earthing systems design software which is easy to use and accurate.
- Standard edition.
- Lightning Shielding Module.
- Fault Current Distribution.
We offer an online technical training course for SafeGrid. Find out more.
Full List of Features
Earthing systems design software which is easy to use and accurate. | ||
Standard | Professional | |
Main Algorithm | ||
Finite element-based calculations for multilayer soils | ![]() | ![]() |
Analyse grids of any shape in 3D | ![]() | ![]() |
Non-equipotential grids analysis (include conductor series impedances) | ![]() | ![]() |
Automatic segmentation for maximum accuracy | ![]() | ![]() |
Grid impedance calculations | ![]() | ![]() |
Grid potential rise | ![]() | ![]() |
Design Settings | ||
Enter soil model explicitly | ![]() | ![]() |
Grid energisation as a fault current or voltage | ![]() | ![]() |
Adjustable frequency | ![]() | ![]() |
Frequency range | Up to 400 Hz | Up to 10 MHz |
Multiple conductor types | ![]() | ![]() |
Specify conductor size/area | ![]() | ![]() |
Extras | ||
Lightning shielding (rolling sphere) design module | ![]() | ![]() |
Conductor sizing calculations to IEEE Std. 80 | ![]() | ![]() |
Build Grid | ||
Above ground conductors | ![]() | ![]() |
Maximum number of segments | 3000 | Unlimited |
Build custom grids of any shape | ![]() | ![]() |
Import grids drawn in AutoCAD | ![]() | ![]() |
Design grids in 3D | ![]() | ![]() |
Add rods at any location | ![]() | ![]() |
Include insulated conductors | ![]() | ![]() |
Specify the faulted conductor location | ![]() | ![]() |
Fault Current Distribution | ||
Full nodal analysis of currents and voltages | ![]() | ![]() |
16 Standard cases for easy modelling | ![]() | ![]() |
Cables and overhead line connections | ![]() | ![]() |
Solid, single-point, cross-bonded cables | ![]() | ![]() |
Earth continuity conductors | ![]() | ![]() |
Overhead lines consisting of multiple sections | ![]() | ![]() |
Multiple feeders (sources of fault current) | ![]() | ![]() |
Soil Modelling | ||
Enter Wenner field resistivity measurements | ![]() | ![]() |
Analyse multiple datasets (traverses) at once | ![]() | ![]() |
Calculate optimal multilayer soil model | ![]() | ![]() |
Account for probe depth at short spacings | ![]() | ![]() |
Manual model adjustment | ![]() | ![]() |
Import measurement data from spreadsheet files | ![]() | ![]() |
Safety Criteria | ||
Surface voltage profiles along a line and over areas | ![]() | ![]() |
Safety Calculations to IEC and IEEE Standards | ![]() | ![]() |
Touch and step voltage calculations | ![]() | ![]() |
Body resistance and permissible body current calculations | ![]() | ![]() |
Foot resistance to IEEE Std. 80 | ![]() | ![]() |
Additional surface layer | ![]() | ![]() |
Display Results | ||
Surface, touch and step voltage plots | ![]() | ![]() |
Leakage currents, Longitudinal currents and Segment voltages plots | ![]() | ![]() |
Interactive 3D plots | ![]() | ![]() |
2D contour plots | ![]() | ![]() |
Plot of safe and unsafe voltages | ![]() | ![]() |
Export plot data to spreadsheet files | ![]() | ![]() |
Reporting | ||
PDF and Microsoft Word Reports | ![]() | ![]() |
Customisable content | ![]() | ![]() |
Add your company logo | ![]() | ![]() |
Ready to try SafeGrid Earthing?
Take SafeGrid Earthing for a test drive with our free trial. You get the ‘Full’ package letting you get a complete idea of how the software can help your business. No credit card details needed.