An example calculation of 132 kV single core and 22 kV three core cable circuits crossing where the derating factor for variation of the crossing angle is examined.
Cable High Voltage (Base)
Cable High Voltage
Accurately determine current ratings of cables with this versatile package.
Calculate current ratings and temperature rise of electric power cables from Low Voltage (LV) up to 500 kV (5 kV d.c.). Calculations based on IEC 60287 and Neher-McGrath methods.
View the Product Page for full details.
Cable High Voltage (Professional)
Cable High Voltage
Accurately determine current ratings of cables with this versatile package.
Calculate the current ratings and temperature rise of electric power cables from Low Voltage (LV) up to any AC or DC voltage level. Calculations based on IEC 60287 (steady-state ratings), IEC 60853 (transient – emergency and cyclic ratings) and Neher-McGrath methods. Calculation results are validated with CIGRE TB 880 (2022).
View the Product Page for full details.
Cable High Voltage (Standard)
Cable High Voltage
Accurately determine current ratings of cables with this versatile package.
Calculate the current ratings and temperature rise of electric power cables from Low Voltage (LV) up to any AC or DC voltage level. Calculations based on IEC 60287 (steady-state ratings), IEC 60853 (transient – emergency and cyclic ratings) and Neher-McGrath methods. Calculation results are validated with CIGRE TB 880 (2022).
View the Product Page for full details.
Cable High Voltage – Standard – Leased (12 Months)
Cable High Voltage
Accurately determine current ratings of cables with this versatile package.
Calculate current ratings and temperature rise of electric power cables from Low Voltage (LV) up to 500 kV (5 kV d.c.). Calculations based on IEC 60287 and Neher-McGrath methods.
View the Product Page for full details.
Cable High Voltage – Standard – Leased (3 Months)
Cable High Voltage
Accurately determine current ratings of cables with this versatile package.
Calculate current ratings and temperature rise of electric power cables from Low Voltage (LV) up to 500 kV (5 kV d.c.). Calculations based on IEC 60287 and Neher-McGrath methods.
View the Product Page for full details.
Cable High Voltage – Standard – Leased (6 Months)
Cable High Voltage
Accurately determine current ratings of cables with this versatile package.
Calculate current ratings and temperature rise of electric power cables from Low Voltage (LV) up to 500 kV (5 kV d.c.). Calculations based on IEC 60287 and Neher-McGrath methods.
View the Product Page for full details.
Emergency and Cyclic Rating Calculations
The Transient Rating module in ELEK Cable HV Software calculates the emergency and cyclic current rating of cables installed in air and buried cables, in accordance with IEC standards.
Finite Element Method Module
The Finite Element Method (FEM) module in ELEK Cable HV Software calculates the current rating of cables in custom arrangements and goes way beyond the limitations of the IEC Standards. For example, users can calculate the current rating for installations with multiple zones of different thermal resistivity.
Magnetic Fields Module
The Magnetic Fields module in Cable HV Software calculates the magnetic field density in micro Tesla µT occurring around a cable, circuit, or a group of circuits. The calculations are based on the Biot-Savart law which explains the fundamental quantitative relationship between electric current which is flowing and the magnetic field it produces.
Modelling of Custom Cables from Datasheets
How to use the Cable Model Editor to model custom cables from manufacturer datasheets and use the cable model obtain the current-carrying capacity.
Training – Soil Drying for High Voltage Power Cable Ampacity Calculations
This video teaches the fundamentals of soil dry out and explains how it affects power cable ampacity calculations. Several example calculations are explained.