0

Your Cart

0
Subtotal: AUD0
No products in the cart.

Earthing/Grounding & Lightning Protection Design Software

Accurate finite element calculations. Any size or shape of system. Multilayer soil modelling. Easy to use.

Click the Interactive Demo below

Pricing Options to Suit Everyone

SafeGrid Earthing is available in two edition choices, and you can choose from perpetual or leased licences. A network licence is available.

Prices are in AUD currency and exclude GST. For a quote in USD, GBP or EUR please contact us.

Perpetual Licence
Leased Licence

SafeGrid (Basic)

1 Year of Updates & Support Included

Earthing systems design which is easy to use and accurate.

*Note to International Buyers:
There will be No Taxes for the purchase of any SafeGrid Products.

SafeGrid (Standard)

AUD9,900Add to cart

1 Year of Updates & Support Included

Complete buried earthing system design package suitable for large grids.

+

SafeGrid (Professional)

Original price was: AUD18,000.Current price is: AUD15,000.Add to cart

1 Year of Updates & Support Included

Above and below ground conductors with high-frequency capability.

+

+

SafeGrid (Standard)

AUD9,900Add to cart

1 Year of Updates & Support Included

Complete buried earthing system design package suitable for large grids.

+

SafeGrid (Professional)

Original price was: AUD18,000.Current price is: AUD15,000.Add to cart

1 Year of Updates & Support Included

Above and below ground conductors with transient and high-frequency capability.

+

Power Bundle

Original price was: AUD27,380.Current price is: AUD19,300.Add to cart

1 Year of Updates & Support Included

All our electrical power systems software.
Save 30% on individual pricing.

+

*Note to International Buyers: There will be No Taxes for the purchase of any SafeGrid Products.

Want to learn more about SafeGrid Earthing? See all features

See How We Compare

We have benchmarked our SafeGrid Earthing Software results against well-known software XGSLab™ and CDEGS™. We show that the results for grid resistance in multilayer soils up to 5 layers are virtually identical.  The results have been analysed.

Why Our Customers Choose SafeGrid Earthing

Get Started with SafeGrid Earthing

With a choice of editions, interactive live demo, free trial download, you could be minutes away from fast, accurate calculations.

A Wide Range of Outstanding Features

Features for Earthing & Grounding Systems Design

An intuitive earthing system design process. Enter your data into the modules and easily switch between them to achieve a safe design.

Grids of any shape or size

Design your earthing system using the in-built editor.
Import grids drawn in 2D or 3D AutoCAD (as a DXF file).

Soil resistivity measurements

Automatic multilayer soil modelling from Wenner and Schlumberger resistivity measurements. Analyse and combine multiple traverses.

Fault current distribution

Achieve a safe design by calculating the actual earth grid current from the prospective (maximum) fault level for single or multiple feeders.

Safety criteria

Determine safe touch and step voltage limits in compliance with IEC/TS 60479, EN 50522 and IEEE Standard 80.

Lightning protection module

Easily perform lightning designs based on rolling sphere method calculations.

Multiple conductor types

Model different conductor types and conductor sizes for horizontal conductors and rods.

A computer screen displaying an electrical graph representing renewables data.
A software running on an electrical laptop displaying a heat map.

Multilayer Finite Element Method calculations

Very accurate algorithms have been developed and proven time and time again through field current injection tests.

Grid Z impedance and GPR

Accurate calculations consider both series Z and mutual impedances (non-equipotential grid analysis) in the frequency domain.

Touch and step voltages

Calculates actual surface, touch and step voltages for comparison with permissible limits.

Plots in 2D or 3D

Analyse touch and step voltages produced by the earthing system during fault conditions.

Custom arrangements

Earthing systems of arbitrary shape, size or configurations.

High-frequency and above-ground structures

Accurate solutions to transient and steady state problems up to megahertz for analysing buried and above ground structures.

Lightning currents

Grid response to lightning strikes including current and potential distributions in the frequency-domain can be calculated.

Soil frequency dependency

There are several methods including CIGRE for automatically considering the variation of soil resistivity and permittivity with frequency.

Complex impedance of conductors

Series and mutual complex impedances are considered for both above and below ground conductors.

Multilayer soils

Can model horizontally layered soils with any number of layers of distinct resistivity and relative permittivity.

Lightning shielding design module

Determine the protected areas by defining the custom locations and heights of lightning masts in accordance with Standard IEC 62305.

Rolling Sphere Method

Automatic algorithm which determines the protected areas or zones of protection in 3D.

Protect levels

Define standard Protection Levels such as PL I (20 m), PL II (30 m), PL III (45 m), PL IV (60 m) or user-defined level.

Import site layout drawings

Overlay lightning masts and draw protection zones on construction drawings to a defined scale.

Multiple masts and equipment heights

Define any number of masts and wires (with sag) between masts. Also define groups and multiple equipment heights.

SafeGrid Lightning Protection Module Report
A plan illustrating the power cables layout within a building.

Advanced reporting

Beautiful, comprehensive and easy to understand reports.

PDF and Word formats

Reports are quickly produced directly to PDF and Microsoft Word document formats.

PDF underlay tool

Use the PDF underlay tool to overlay the soil voltage plots onto your construction drawings.

Include your company logo

Personalise the reports by adding your company logo image.

Custom reports

Choose the calculation results to include or exclude from the reports.

Get Started with SafeGrid Earthing

With a choice of editions, interactive live demo, free trial download, you could be minutes away from fast, accurate calculations.

Frequently Asked Questions

Yes, SafeGrid is used worldwide, so our users can model using metric or imperial units.

SafeGrid provides safety limit calculations in accordance with international standards IEEE Std. 80 and IEC 60479. The safety limit calculations prescribed by all other country-specific standards or guides are based on either of these.

Yes the main algorithm takes into account the voltage drops along conductors (quasi-static transversal impedance) due to both the self and mutual impedances and propagation effects.

Yes earthing systems comprising conductors in any arrangement.  Multiple earthing systems can be modelled.  CAD files (.dxf format) can be imported.

The fault current module is a useful tool to calculate the voltages and currents or short-circuit currents, fault current distributions or split factors. The algorithm is based on a general for of nodal analysis with all mutual impedances considered.

Complex multiple feeder configurations can be modelled consisting of cable circuits or overhead line feeders.

Yes Wenner-based field measurements can be entered and an optimal multilayer soil model calculated automatically.

Suitable for any buried earthing system from single rod in an LV application to a huge EHV substation application for DC and power frequencies.

The SafeGrid main algorithm is

Via instant download. Link to download, activation code and invoice emailed immediately (24/7) after purchase.

Each licence of ELEK SafeGrid can be used by up to 2 users at the same time for perpetual licences and 1 user at a time for leased licences. You can install the software onto any number of PCs in your business in any locations. A simple online 24/7 activation process is used. The software licence is easily deactivated by any user and moved between PCs.

Updates and Support payment is due after the first year which is 20 % of the current licence price.

We regularly update our software adding new features and improvements.

Yes, you can upgrade from the Standard to Professional edition (for example) at any time, by simply contacting us and paying the difference.

We're Here To Help

Our software is designed to be simple and intuitive, but if you need a helping hand, we have a support team and range of online resources to help get you get up to speed quickly.

A software tool featuring a clipboard with a check mark on it for electrical substation management.

First Class Support

Our expert team is on-hand to assist you with any questions you have or assistance you need with our software range.

A software icon displaying a book with an electrical graph.

Top Notch Documentation

Dive into our online software manual to learn everything you need, or check out our easy to follow tutorials.

SafeGrid Earthing: Software Manual | Tutorials
A green square with an electrical icon.

Expand Your Thinking

If you want to broaden your knowledge, we have a range of videos and in-depth articles on a wide range of topics.

Learn: Videos | Articles

Get Started with SafeGrid Earthing

With a choice of editions, or a free trial, and instant downloads, you could be minutes away from fast, accurate calculations.

elek about team - SafeGrid Earthing Software

About Us

We're Here For You

Electrotechnik is an electrical software company founded in 2009.

We provide software solutions to the electrical design industry. Our vision is to provide the world’s best and most innovative electrical software for engineers and electrical contractors.

Our software is developed and supported by an experienced team from our head office.

Read about our story.

SafeGrid Earthing Free Trial

  • Fill out your details below to begin your trial. Once your information has been submitted you'll be able to download the software.

  • This field is for validation purposes and should be left unchanged.