पावर सिस्टम अर्थिंग डिज़ाइन के लिए मानक

Reference list of standards for power systems earthing/grounding categorised by applications

विषयसूची

Who created this list of earthing Standards?

Experienced electrical earthing design engineers with years of hands-on project expertise have developed this reference list of standards for power systems earthing.

These professionals have drawn on their extensive knowledge to compile a comprehensive guide that ensures compliance, safety, and reliability across various applications. From substations to renewable energy systems, the standards outlined here reflect industry best practices and are tailored to meet the diverse needs of modern electrical installations.

Where do the important earthing standards come from?

The most important earthing standards are developed by globally recognised organisations that specialise in electrical engineering, safety, and power system design. These organisations bring decades of expertise and research to create guidelines that ensure the safe operation of power systems across various industries. Here is an overview of the key contributors:

1. International Electrotechnical Commission (IEC)

The IEC is a global standards organisation that focuses on electrical, electronic, and related technologies. It develops internationally accepted standards that ensure compatibility, safety, and efficiency in power systems worldwide.

2. Institute of Electrical and Electronics Engineers (IEEE)

The IEEE is a leading professional association for electrical and electronics engineering. It publishes highly regarded standards that address technical aspects of power systems, including grounding, resistivity measurement, and renewable energy applications.

3. Australian/New Zealand Standards (AS/NZS)

AS/NZS standards are tailored to the specific requirements of Australia and New Zealand. They address local safety regulations, environmental conditions, and industry needs, ensuring compliance with regional practices.

4. British Standards Institution (BSI)

The BSI develops standards that serve as benchmarks for safety and performance in electrical installations. Its work is widely adopted in the UK and internationally for ensuring effective earthing practices.

5. International Council on Large Electric Systems (CIGRE)

CIGRE is a global organisation dedicated to advancing power system technology through research and technical guidance. It provides specialised insights into grounding system design and lightning performance for transmission lines.

6. Energy Networks Association (ENA)

The ENA represents electricity transmission and distribution network operators in regions such as the UK and Australia. It produces detailed guidelines for designing, testing, and maintaining earthing systems in power networks.

7. Electric Power Research Institute (EPRI)

EPRI conducts research to enhance the reliability, efficiency, and safety of power systems. Its contributions include innovative guidelines for emerging technologies like high-voltage direct current (HVDC) systems. These organisations collectively shape the global framework for earthing standards, ensuring consistency, innovation, and safety across diverse applications in power systems engineering.

List of Standards for Power Systems Earthing Design

Power systems earthing is a critical component of electrical safety and performance. Below is a comprehensive list of standards categorised by their specific applications, with additional standards included.

1. Substation Earthing

2. Testing of Earthing Systems

3. Touch/Step Voltage Limits

4. Renewable Energy Systems

5. Metallic Pipelines Safety

6. Industrial & Commercial Earthing

7. Overhead Lines

8. High Voltage DC Systems

9. Data Centres Earthing

10. Telecommunications

11. Fault Current Distribution

सेफग्रिड अर्थिंग सॉफ्टवेयर

मानकों के अनुपालन में आसानी से सुरक्षित अर्थिंग सिस्टम डिजाइन करें।

संबंधित आलेख:

समझें कि सॉफ्टवेयर सिमुलेशन किस प्रकार ग्रिड प्रतिबाधा परीक्षणों को बढ़ाते हैं, तथा भू-सम्पर्कन प्रणाली डिजाइन और प्रदर्शन मूल्यांकन में सटीकता और दक्षता में सुधार करते हैं।
यह रिपोर्ट बताती है कि केबल ट्रांसमिशन लाइनों से जुड़े सबस्टेशनों के लिए सटीक अर्थ फॉल्ट करंट विश्लेषण कैसे किया जाता है। सरल केबल और ओवरहेड ट्रांसमिशन लाइनों के लिए अर्थ फॉल्ट करंट को पहले समझाया गया है। इसके बाद, हाइब्रिड केबल ट्रांसमिशन लाइनों से जुड़े दो केस स्टडी प्रस्तुत किए गए हैं।
तांबे को अक्सर इसके बेहतर विद्युत गुणों के लिए पसंद किया जाता है, जबकि एल्यूमीनियम और गैल्वेनाइज्ड स्टील को लागत-प्रभावशीलता के लिए चुना जाता है। कॉपर-क्लैड स्टील लागत और प्रदर्शन के बीच संतुलन प्रदान कर सकता है। यह लेख दर्शाता है कि विभिन्न परिदृश्यों के लिए कौन सा विकल्प सबसे अच्छा है।
तकनीकी मार्गदर्शिका में विद्युत प्रणालियों, स्थानीय डब्ल्यूटीजी और संयुक्त भूयोजन प्रणाली डिजाइन, स्पर्श और चरण वोल्टेज खतरों, मृदा विद्युत प्रतिरोधकता माप, भूयोजन दोष धाराओं, भूयोजन प्रणाली सॉफ्टवेयर मॉडलिंग और पवन फार्मों के लिए भूयोजन के सत्यापन परीक्षण के बारे में बताया गया है।
मानकों के अनुसार, सबस्टेशनों में कुचला हुआ पत्थर या बजरी बिछाने के दो कारण हैं, जैसा कि इस लेख में बताया गया है।
सबस्टेशन अर्थ ग्रिड पर अर्थ फॉल्ट के दौरान, पृथ्वी की ओर प्रवाहित करंट वोल्टेज ग्रेडिएंट उत्पन्न करेगा। एक अर्थ ग्रिड जो ठीक से डिज़ाइन किया गया है, वह सुरक्षित रूप से जमीन में करंट को फैलाएगा।

इस लेख को प्रिंट करें: