Power Systems Technical Articles

Our experts continuously work on power systems problems, and we share solutions with Practical Reference Articles.

The main topics are earthing system modeling, power cable ratings, HV/LV electrical design, protective device coordination, and arc flash studies. We cover IEC and IEEE standards.

Join 23K+ engineers and get our latest technical articles direct to your inbox as they are releasedJayson Patrick

This field is for validation purposes and should be left unchanged.
Photo of Jayson Patrick for Technical Articles page about electrical power systems Design

Choose the article category

The definition of “touch voltage” is the voltage between accessible exposed and extraneous conductive parts that may lead to the risk of electric shock in the event of an electrical fault. This article covers AS/NZS 3000, BS 7671, and NFPA 70E rules concerning touch voltages and provides the equations for calculations.
8 mins read
There are several international Standards (AS/NZS, BS and IEC) which cover requirements for protection coordination of low voltage electrical systems and this article provides a summary of those as a reference.
9 mins read
We performed ampacity calculations for hundreds of industrial and utility power cables from Southwire. The assumptions used for modelling in the software are explained. The calculated ampacities were all within 3 % of the values given in ICEA and NEC standards.
4 mins read
There are two reasons, according to the standards, why crushed rock or gravel is laid in substations, as explained in this article.
11 mins read
We compare the best and latest earthing and grounding system design software including SafeGrid, CDEGS, XGSLab, ETAP and more based on technical features and compares price.
10 mins read
How to design and model earthing systems for a solar PV farm to the latest practices and standards. Soil resistivity, fault levels, and safety are covered.
8 mins read
Most power cables have a design life of between 20 to 30 years. If the cables are not fully loaded, they are expected to last beyond their design life. The insulation is the weakest part of a cable. Montsinger's Rule states: Insulation life is halved by a temperature increase of 8 to 10 ˚C. An example calculation using the Arrhenius equation is provided.
5 mins read
The widely accepted maximum operating temperature of XLPE insulated power cables under “normal use” conditions is 90 ˚C. During emergencies, the temperature of a buried cable may be permitted to exceed this temperature. The duration considered for such emergencies ranges from 10 minutes up to 15 days. In many countries, XLPE-insulated cables are allowed to operate up to 100-105 ˚C for short durations.
10 mins read
Understand how software simulations enhance grid impedance tests, improving accuracy and efficiency in earthing system design and performance evaluation.